Excerpted from The Psychophysiological Assessment of Female Sexual Function by Cindy M. Meston, Ph.D. The psychophysiological assessment of female sexual function has a relatively short history in sexology (Rosen & Beck, 1998). It wasn't until 1975, when Sintchak and Geer introduced the vaginal photoplethysmograph, that the first practical and reliable measurement device for vaginal blood flow was available. The introduction of the vaginal photoplethysmograph spurred great research interest in the area of female sexual arousal throughout the late 70s and early 80s. A number of publications arose that examined vaginal responses during various experimental manipulations, and assessed the diagnostic implications of this new measurement device. Since then, advances in understanding the female sexual response have slowed considerably. In fact, over the past decade and a half, only a handful of laboratories worldwide have focused exclusively on studying the female psychophysiological sexual response.
There are two components of the signal that can be derived from the photoplethysmograph. When the signal is coupled to a Direct Current (CD) amplifier, a measure of vaginal blood volume (VBV) is obtained. VBV is believed to reflect slow changes in the pooling of blood in the vaginal tissue (Hatch, 1979). The DC signal is used at low sensitivity and the standard dependent variable is change from levels of VBV at baseline. Because there is no discernible zero point with VBV, absolute measures of blood volume cannot be detected, hence the need to measure in units of blood volume change. When the signal is AC-coupled (alternating current), a measure of vaginal pulse amplitude (VPA) is obtained. VPA is believed to reflect phasic changes in Advantages for using vaginal photoplethysmography as a technique for assessing female sexual arousal include (a) the ability of subjects to insert the probe in privacy, without the assistance of a researcher, (b) the ability to measure blood volume changes over relatively long periods of time without harm or discomfort to the subject, and (c) the relatively short period of time required for VBV and VPA levels to return to baseline, which allows for multiple, sequential stimulus recordings. Disadvantages of using this technique include (a) the inability to measure sexual responses during orgasm due to the sensitivity of the probe to movement artifacts, and (b) the lack of a sound theoretical basis for interpreting what exactly the signal means. As noted by Levin (1992), in some tissues an increase in VPA may represent a restriction of venous drainage rather than vasodilation per se. In addition, VBV and VPA signals provide no information as to whether the vasodilation is occurring in the arteries, arterioles, capillaries, venules or veins (Levin, 1992). |